Provisioning steps for W52P / W56P / W56H / W60P
Vodafone Business with RingCentral only supports the following versions of this cordless phone. If your cordless phone handsets or base do not meet this requirement, you may not be able to provision or use the devices.
Note: Only four paired handsets per base station are supported. Pairing the 5th handset may result in some users not making phone calls.
Base Station
:
Hardware version: 25.1.0.0.0.0.0 or higher
Software version: 25.50.0.20 or higher
You may need to manually update the software/firmware version of the base station from 25.50.0.20 to version 25.80.25.1.
Handsets
:
Hardware version: 61.0.0.1 or higher
Software version: 61.80.0.10 or higher
Please refer to the manufacturer's documentation for instructions on identifying the version numbers.
Admin portal > Phone system > Phones & devices > User phones
.
- Select an Existing phone from the list, then click
Setup & Provision
.
- Click
Yealink IP Phones
, then select the Yealink phone model to provision.
- Click
Next
.
- Reset the existing configuration on your Yealink phone.
- Enter the phone’s
MAC address
, then click
Next
.
- Access your phone’s web interface.
- In the Yealink phone’s web interface, navigate to
Phone > Auto Provision
.
- Enter the
Provisioning URL
in the
Provisioning Server
field.
- Yealink W52P: https://yp.ringcentral.com/provisioning/yealink/W52P
- Yealink W56P: https://yp.ringcentral.com/provisioning/yealink/$PN
- Yealink W56H: https://yp.ringcentral.com/provisioning/yealink/W56H
- Yealink W60P: https://yp.ringcentral.com/provisioning/yealink/$PN
- Ensure that the
User Name
and
Password
fields are blank.
- Click
Confirm
.
- Click
Autoprovision Now
.
Note: Your phone will reboot and provision itself. Please do not power off or disconnect your device during the upgrade process. Click
Done
on the
Setup & Provisioning
window when finished.
Reset the existing configuration on your Yealink phone
You may perform these steps on any handset paired to your cordless phone base station.
- Press
OK > Status > System status
to obtain the IP address of the cordless phone base station.
- Enter the IP address into the address bar of your web browser and press the
Enter
key.
- Log in to the cordless phone’s web interface. The default username is
admin
, and the default password is
admin
.
- Navigate to
Phone > Upgrade > Reset to Factory
.
- Click
Reset Now
.